Intrinsically Safe Antenna Coupler SOLEXY – RX Series
$58.1
$107.49
Description Intrinsically Safe Antenna Coupler SOLEXY – RX Series ATEX Zone 1/21 Class I Division I Class II Division I IECEx ATEX Apparatus Certified IECEx apparatus certified The USA and Canada Listed Equipment (cQPSus) RXN3S0200RXN: optimized frequency range from 700MHz to 3,9GHz & 4,6GHz to 6GHz RXN3S0200JXN: optimized frequency range from 100MHz to 1,4 GHz N Female antenna connection suitable for N Male antenna 3/4” npt-m thread connection Stainless steel housing RP-SMA Female coaxial connector suitable for RP-SMA Male radio connection double connector execution, no coax cable max RF power input 2 Watts (33dBm) ambient temperature range -40°C to 85°C (T5) / 70°C (T6) Introducing the new Intrinsically Safe Antenna Coupler SOLEXY – RX Series is designed to be used directly with listed explosion housings or conduit fittings. This coupler is an integrated blocking circuit that prevents hazardous energy from reaching the antenna if a radio, modem, or access point failure occurs. It also allows antenna removal in hazardous areas. The coupler’s powerful design allows for the connection to approximately any radio and antenna. It is a highly flexible cost-effective solution to hazardous area radio system deployment. The coupler can also be used as a cable bulkhead. Solexy I S Antenna Barrier The Antenna Coupler function is to block DC signal and provide a very high impedance to low-frequency AC signal. Fitting is approved for hazardous locations and can be installed with a simple wrench. Features Short Circuit Protection – includes integrated blocking circuitry Environmental Protection – All required circuitry is recessed into the fitting and encapsulated against the harsh environment. Certification – The RX series is certified ATEX, IECEx, and for USA and Canada as an apparatus, and can be installed per the conditions of acceptability, without further assessment. North America approval (the USA and Canada ) includes Class and Divisions and Zones. IECEx certifications are issued from an Australian noticed body, therefore RX can be installed in Queensland mine. No Sealing Fitting Required – Permits a wide variety of passive antennas to be installed in hazardous areas. Antennas may be removed and/or installed with power on. Perfect for a cable bulkhead connection. Isolated Antenna Ground – optional antenna ground isolation ( RX 1..) from housing ground, combined with the positive circuit, solves ground loop issues in case of remotely mounted antennas and prevents potential ground noise to interfere with RF signal. Properties Solexy’s patented (7,057,577) Explosion-Proof Antenna Coupler permits the installation of non-Ex-certified antennas in hazardous areas. This coupler is designed to be used directly with listed explosion-proof housings or conduit fittings. An integrated blocking circuit prevents hazardous energy from reaching the antenna if a radio, modem, or access point failure occurs. It also allows for antenna removal in hazardous areas. The coupler’s robust design allows for connection to practically any radio and antenna. It is a highly flexible and cost-effective solution to hazardous area radio system deployment. The coupler can also be used as a cable bulkhead. Fitting is approved for hazardous locations and can be installed with a simple wrench. Specifications ATEX certification nr. TÜV CY 18 ATEX 0206158 XEx I M2 (M1) Ex db mb [ia Ma] I Mb II 2 (1) G Ex db mb [ia Ga] IIA/IIB/IIC T5…T6 Gb II 2 (1) D Ex mb tb [ia Da] IIIC T80°C…T100°C Db Standard Ref.EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-18, EN 60079-31 IECEx certification nr. IECEx MSC 19.0001XEx db mb [ia Ma] I Mb Ex db mb [ia Ga} IIA/IIB/IIC T5….T6 GbEx mb tb [ia Da] IIIC T80°….T100°C Db Standard Ref.IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-18, IEC 60079-31 USA & Canada certification cQPSus LR-1504-3Class I, Division 1, GROUP ABCD; Class II, Division 1, GROUP EFG [Ex ia Ga] IIC; [Ex ia Da] IIIC Class I, Zone 1, AEx db mb [ia Ga] IIA/IIB/IIC T6...T5 Gb Zone 21, AEx mb tb [ia Da] IIIC T80°C...100°C Db Ex db mb [ia Ga] IIA/IIB/IIC T6...T5 Gb Ex mb tb [ia Da] IIIC T80°C...T100°C Db Standard Ref.CAN/CSA C22.2 No. 60079-0 UL 60079-0 CAN/CSA C22.2 No. 60079-1 UL 60079-1 CAN/CSA C22.2 No. 60079-11 UL 60079-11 CAN/CSA C22.2 No. 60079-18 UL 60079-18 CAN/CSA C22.2 No. 60079-31 UL 60079-31 CAN/CSA C22.2 No. 60950-1 UL 60950-1 CAN/CSA C22.2 No. 25-17 UL 1203 CAN/CSA C22.2 No. 30-M1986 CAN/CSA C22.2 No 157 UL 1203 UL 508 CAN/CSA C22.2 No. 94.2-15 UL 508 NEMA 250-2014 Maximum Fault Voltage250VDC, 250VAC 50-60Hz Approximate Weight0.32 kg (70.6 lb) NEMA ratingProvides a NEMA 4X connection when connected to a NEMA 4X rated enclosure Impedance50 Ω Ambient Temperature Range-40°C (-40°F) to 85°C ( 185°F) when max RF input = 2W (T5) (standard) -40°C (-40°F) to 80°C ( 176°F) when max RF input = 6W (T5) (optional, consult factory) -40°C (-40°F) to 70°C ( 158°F) when max RF input = 2W (T6) (standard) -40°C (-40°F) to 65°C ( 149°F) when max RF input = 6W (T6) (optional, consult factory) Approximate Insertion Loss (dB) FrequencyJ versionR version 100 MHz1.3- 500 MHz0.41.2 1.4 GHz0.40.6 1.7 GHz0.50.6 2.5 GHz0.80.8 3.9 GHz-1.1 4.9 GHz-1.8 5.4 GHz-1.4 6.0 GHz-2.0 Intrinsically Safe Antenna Coupler SOLEXY – RX Series Certifications: Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-ATEX-Certificate Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-IECEx-Certificate Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-QPS-Certificate Intrinsically Safe Antenna Coupler SOLEXY – RX Series Other Resources: Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-Data-Sheet Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-Brochure Intrinsically-Safe-Antenna-Coupler-SOLEXY-RX-Series-Control-Drawing
Productivity